interlock_constraint#

Represents a restriction on which gates in a tunnel system that can be open/closed at the same time.

Input connections

tunnel

Output connections

tunnel

License

SHOP_TUNNEL

Release version

13.5.1.a

Attributes#

min_open#

Data type: timeseries. Unit: NO_UNIT.

Minimum limit for how many objects connected to this constraint that can be open simultaneously.

max_open#

Data type: timeseries. Unit: NO_UNIT.

Maximum limit for how many objects connected to this constraint that can be open simultaneously.

forward_switch_time#

Data type: double. Unit: NO_UNIT.

Minimum number of hours that plant below must be stopped after closing tunnels connected to this constraint.

backward_switch_time#

Data type: double. Unit: NO_UNIT.

Minimum number of hours that plant below must be stopped after closing tunnels connected from this constraint.