gen_reserve_capability#
An object describing different types of reserve delivery capabilities for a generator unit.
Input connections |
|
Output connections |
|
License |
SHOP_RESERVE_GROUP |
Release version |
14.4.0.0 |
Attributes#
reserve_type_name#
The reserve product this reserve capability definition is valid for. Can be either FCR_N_UP/DOWN, FCR_D_UP/DOWN, FRR_UP/DOWN, or RR_UP/DOWN (xUnit: NO_UNIT, yUnit: NO_UNIT)
p_extended#
Defines an extended production limit for delivering this reserve type. It should be higher than the maximum generator production for upward reserves or below the minimum production for downward reserves. (xUnit: NO_UNIT, yUnit: MW)
schedule#
A schedule for how much reserve capacity of the specified type that must be delivered on the generator (xUnit: NO_UNIT, yUnit: MW)