time: starttime: 2018-02-27 00:00:00 endtime: 2018-02-28 00:00:00 timeunit: hour timeresolution: 2018-02-27 00:00:00: 1 model: reservoir: Reservoir1: max_vol: 12 lrl: 90 hrl: 100 vol_head: ref: 0 x: - 0 - 12 - 14 y: - 90 - 100 - 101 start_head: 92 inflow: 2018-02-27 00:00:00: 10 energy_value_input: 39.7 Reservoir2: max_vol: 5 lrl: 40 hrl: 50 vol_head: ref: 0 x: - 0 - 5 - 6 y: - 40 - 50 - 51 start_head: 43 inflow: 2018-02-27 00:00:00: 0 plant: Plant1: outlet_line: 40 main_loss: - 0.0002 penstock_loss: - 0.0001 generator: P1G1: penstock: 1 p_min: 25 p_max: 100 p_nom: 100 gen_eff_curve: ref: 0 x: - 0 - 100 y: - 95 - 98 turb_eff_curves: - ref: 90 x: - 25 - 90 - 100 y: - 80 - 95 - 90 - ref: 100 x: - 25 - 90 - 100 y: - 82 - 98 - 92 startcost: 2018-02-27 00:00:00: 500 river: outlet: upstream_elevation: 50 flow_cost: 2018-02-27 00:00:00: 10 market: Day_Ahead: max_buy: 2018-02-27 00:00:00: 9999 max_sale: 2018-02-27 00:00:00: 9999 buy_price: 2018-02-27 00:00:00: 20.01 2018-02-27 06:00:00: 40.01 sale_price: 2018-02-27 00:00:00: 19.99 2018-02-27 06:00:00: 39.99 pump: P1P1: penstock: 1 p_min: 38 p_max: 42 p_nom: 40 gen_eff_curve: ref: 0 x: - 0 - 50 y: - 100 - 100 turb_eff_curves: - ref: 40 x: - 80 y: - 87 - ref: 50 x: - 70 y: - 86 - ref: 60 x: - 60 y: - 85 startcost: 2018-02-27 00:00:00: 500 connections: - from: Reservoir1 to: Plant1 - from: P1G1 to: Plant1 - from: P1P1 to: Plant1 - from: Plant1 to: Reservoir2 - from: Reservoir2 to: outlet commands: - start sim 3 - set code /inc - start sim 3